beautypg.com

Vermont castings ewf36a, Minimum wall clearances, Minimum hearth extension dimensions – Majestic Appliances EWF36A User Manual

Page 17

background image

17

Vermont Castings EWF36A

20005167

FP1201

Fig. 25 Combustible side wall protection and hearth extension dimensions.

Minimum Wall Clearances

WITH
Noncombustible
Surround Facing

WITHOUT
Noncombustible
Surround Facing

Minimum Hearth Extension Dimensions

(for On-Site Construction)

G

H

G

J

Seal cracks
between the
fireplace
and hearth
extension with
noncombustible
material

"Z" Safety strips
must overlap

¹⁄₂

" minimum

May install
noncombustible
decorative
covering
OR .018" min.
sheet metal

Fireplace
Opening

Combustible
Floor

9

¹⁄₂

" Required

Firebox

Opening

A - Min. clearance
to combustible
perpendicular wall

B - Min. clearance
to combustible
perpendicular wall when
using noncombustible wall shield*

Side
Wall

Side
Wall

F**

C**

E

E

D

4" Brick
(Example material)

Combustible material permitted within shaded area.

* Noncombustible wall shield requires 1" EH2416

insulation (minimum R Value = 1.85) between decorative
noncombustible rigid covering and combustible wall.
Minimum height and width is 40" x 40".

** Dimension/degree of angle will vary depending on thickness

of noncombustible surround facing.

4"

NOTE: No material may
cover black cast face.
Hearth extension must be
flush with bottom of fireplace.

1" Min.

1" Min.
EH2416 or
Equal "R" Value

Shaded area starts
1/2" away from
edge of unit

A

B

C

D

E

F

G

H

J

EWF36A

24”

12”

17

°

25

°

12”

8”

8”

18”

57”

610mm 305mm

305mm

203mm 203mm

457mm 1448mm