Chapter 4 - V.22bis Commands
Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide
32
+ITF
Transmit Flow Control Thresholds
The +ITF command determines the flow control thresholds used by the modem for transmit data from the DTE. This
optional compound parameter allows the DTE to determine the input buffer size in the modem for data on circuit 103
(transmit data) from the DTE, to control the thresholds used for flow control of such data, and to control how often the
modem reports to the DTE the number of octets in this buffer. The DTE can adjust its own thresholds for flow control
of data on circuit 104 (received data) from the modem.
Syntax
+ITF=[
Defined Values
Synchronous Access and Frame Tunneling modes. Default
For the
interface and the Synchronous Access protocol layer; i.e., the buffer count includes all octets, including EM
codes, received from the DTE, with the exception of DC1 and DC3 if these are used to signal
The modem returns the ERROR result code if the DTE specifies that the
less than or equal to the
modified.
Synchronous Access and Frame-Tunneling modes. Default
Reporting Selected Options
The modem sends a string of information text to the DTE consisting of selected options in response to the following
command:
+ITF?
The response is:
+ITF:
Example:
+ITF?
+ITF: 255,64,0 Default values
Reporting Supported Options
The modem sends a string of information text to the DTE consisting of supported options in response to the following
command:
+ITF=?
The response is:
+ITF: (list of supported
Example:
+ITF=?
+ITF: (0-255),( 0-255),(0)
The maximum reported
overrun indication to the DTE.