beautypg.com

Scanner and cable terminations, Scanner pinout connections – Metrologic Instruments MS9524 User Manual

Page 46

background image

42

1

10

S

CANNER AND

C

ABLE

T

ERMINATIONS

Scanner Pinout Connections

MS9524/44-41

RS-232C and Light Pen Emulation

Pin

Function

1

Ground

2

RS-232 Transmit Output

3

RS-232 Receive Input

4

RTS Output

5

CTS Input

6

DTR Input/LTPN Source

7

Reserved

8

LTPN Data

9

+5VDC

The MS9524 and MS9544
scanner interfaces terminate to
a 10-pin modular jack. The
serial # label indicates the
interface enabled when the
scanner is shipped from the
factory.

10

Shield Ground

MS9524/44-47 Keyboard Wedge &

Stand-Alone Keyboard

Pin

Function

1

Ground

2

RS-232 Transmit Output

3

RS-232 Receive Input

4

PC Data

5

PC Clock

6

KB Clock

7

PC +5V

8

KB Data

9

+5VDC

10

Shield Ground

MS9524/44-11 IBM 468X/469X

Pin

Function

1

Ground

2

RS-232 Transmit Output

3

RS-232 Receive Input

4

RTS Output

5

CTS Input

6

DTR Input

7

IBM B-Transmit

8

IBM A+ Receive

9

+5VDC

10

Shield Ground

Continued next page.