beautypg.com

MITSUBISHI ELECTRIC 882.00273.00 User Manual

Page 95

background image

BLENDER ALARMS

1 (R) alarm_number,D1876 (see below for description)

2 (R) hop1_out_of_material,M561

3 (R) hop2_out_of_material,M562

4 (R) hop3_out_of_material, M563

5 (R) hop4_out_of_material, M564

6 (R) hop5_out_of_material, M565

7 (R) hop6_out_of_material, M566

8 (R) hopper_over_max_alarm,M570

9 (R) empty_weight_exceeded,M571

10 (R) inventory_cleared,M572 (use this bit to record when an operator cleared the inventory at the
blender)

11 (R) power_interruption,M576 (this alarm engages when the PLC loses power during a batch)

12 (R) hop1_low_level,M618 (this alarm is only available if the hoppers have low level prox switches)

13 (R) hop2_low_level,M619 (this alarm is only available if the hoppers have low level prox switches)

14 (R) hop3_low_level,M620 (this alarm is only available if the hoppers have low level prox switches)

15 (R) hop4_low_level,M621 (this alarm is only available if the hoppers have low level prox switches)

16 (R) hop5_low_level,M622 (this alarm is only available if the hoppers have low level prox switches)

17 (R) hop6_low_level,M623 (this alarm is only available if the hoppers have low level prox switches)

18 (R) plc_battery_low,s:M743

BF1-615.3

Chapter 7: 6BAppendix

95 of 101