Performance curves, 1-1.capacity and the input curves – MITSUBISHI ELECTRIC MXZ-32SV User Manual
Page 13
13
10
The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions,
since operating conditions vary according to the areas where these units are installed. The following information has been pro-
vided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198 ~ 264V
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature :
°CWB
(2) Indoor outlet air wet-bulb temperature :
°CWB
(3) Outdoor intake air dry-bulb temperature :
°CDB
(4) Total input:
W
(5) Indoor intake air dry-bulb temperature :
°CDB
(6) Outdoor intake air wet-bulb temperature :
°CWB
(7) Total input :
W
Indoor air wet/dry-bulb temperature difference on the left side of the chart on page 14 and 15 shows the difference
between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your refer-
ence at service.
How to measure the indoor air wet-bulb/dry-bulb temperature difference
1. Attach at least 2 sets of wet-and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet-and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2. Attach at least 2 sets of wet-and dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of room.
5. Press the EMERGENCY OPERATION switch once(twice) to start the EMERGENCY COOL(HEAT) MODE.
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
INDOOR UNIT
OUTDOOR UNIT
}
}
Cooling
Heating
PERFORMANCE CURVES
Wet-and dry-bulb
thermometers
Wet-and dry-bulb
thermometers
07 class
7.5
7.0
6.4
5.9
5.3
4.8
8.7
8.1
7.4
6.8
6.2
5.6
10.8
10.1
9.3
8.5
7.7
7.0
6.7
6.2
5.8
5.3
4.8
4.3
18 class
12 class
09 class
10-1-1.CAPACITY AND THE INPUT CURVES
32.3
29.8
27.3
24.9
22.4
19.9
17.4
14.9
38.2
35.3
32.4
29.4
26.5
23.5
20.6
17.6
25.9
23.9
21.9
19.9
17.9
15.9
13.9
11.9
27.7
25.6
23.4
21.3
19.2
17.0
14.9
12.8
07 class
09 class
12 class
18 class
OB254-1.qxp 03.1.16 4:33 PM Page 13