beautypg.com

Water service/drains, Water supply, Drain connections – Manitowoc Ice UNDERCOUNTER QM30 User Manual

Page 13: Water supply and drain line sizing/connections

background image

Section 2

Installation Instructions

Part Number 000001772 07/08

2-5

Water Service/Drains

WATER SUPPLY

Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, remove
chlorine, and improve taste and clarity.

Follow these guidelines to install water inlet lines:

Connect to potable water supply only.

Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)

If water pressure exceeds the maximum
recommended pressure, obtain a water pressure
regulator from your Manitowoc distributor.

Install a water shut-off valve for both the ice making
and condenser water lines (if applicable).

Insulate water lines to prevent condensation.

DRAIN CONNECTIONS

Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:

Drain lines must have a 2.5 cm (1 inch) drop per 1
meter (40 inches) of run, and must not create traps.

The floor drain must be large enough to
accommodate drainage from all drains.

Insulate the bin drain line to prevent condensation.

WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS

1

Min. = Minimum

2

Max. = Maximum

3

A 3/4” by 11-1/2 threads per inch to 14 threads per inch adapter is factory installed. Remove this adapter if 11-1/2

threads per inch connection is desired.

Important

If you are installing a Manitowoc Tri-Liminator
water filter system, refer to the Installation
Instructions supplied with the filter system for ice
making water inlet connections.

Important

The water inlet line is connected to the water
valve. This valve is located just behind the front
panel of the ice machine.

! Caution

Plumbing must conform to state and local codes.

Water

Temperature

Water

Pressure

Ice Machine

Fitting

Tubing Size Up to Ice

Machine Fitting

Ice Making

Water Inlet

10

°C (50°F)

Min.

1

30

°C (86°F)

Max.

2

240 kPA (34.8 psi)

Min.

1

620 kPA (89.9 psi)

Max.

2

3/4”

male hose

connection

3

0.95 cm (3/8”)

minimum

inside diameter

Ice Making/

Bin Water

Drain

——

——

1.59 cm (5/8”)

inside

diameter flexible

hose

1.59 cm (5/8”)

minimum

inside diameter