Rs-485 cable wiring for opt8j – Moxa Technologies INTELLIO C218 User Manual
Page 80

5-10
Intellio C218Turbo /PCI User's Manual
RS-485 Cable Wiring for Opt8J
One RS-485 connection box designed for
Intellio C218Turbo/PCI is:
Opt8J: Connection box with 8 female RS-422/485 DB25 ports. Set the port switch
to ON position.
The Opt8J supports only 2-wire half-duplex RS-485 communication. Data+/-
pins are served for both data transmitting and receiving, depending on the RTS
signal.
RS-485 Pinouts for Opt8J:
Opt8J
3
Data+(B)
7
GND
16
Data-(A)
Multidrop RS-485 Half-duplex
Point-to-Point RS-485 Half-duplex
Opt8J
RS-485 Device 1
Opt8J
RS-485 Device
Master
Slave
3 Data+(B)
Data+(B)
3
Data+(B)
Data+(B)
16 Data-(A)
Data-(A)
16 Data-(A)
Data-(A)
7 GND
GND
7
GND
GND
RS-485 Device N
Slave
Data+(B)
Data-(A)
GND
See Section “RS-485 Programming” of Chapter “Serial Programming Tools” for
more Opt8J RS-485 programming details.
3 Data+ (B)
7 GND
Data- (A) 16