1

Normal Shutdown Procedure

To shutdown the generator use the following procedure:

1. Place both the main, GFCI, and aux. circuit breakers

as shown in Figure 20 to the OFF position.

2. Set the Speed Control Switch to the START/IDLE position

as shown in Figure 22 and let the engine cool for 3-5
minutes with no load applied.

3. Turn the ignition key counter-clockwise to the STOP

position. When the engine has stopped, remove key.
Place key in a safe place where it will not be lost.

4. Inspect entire generator for any damage or loosening of

components that may have occured during operation.

DCA-10SPX4 — GENERATOR SHUT-DOWN PROCEDURES

NEVER stop the engine suddenly except in an emergency.

WARNING - SHUTTING DOWN THE GENERATOR

Emergency Shutdown Procedure

1. Turn the ignition key counter-clockwise to the STOP

position. When the engine has stopped, remove key.
Place key in a safe place where it will not be lost.

2. Place both the main, GFCI, and aux. circuit breakers

as shown in Figure 20 to the OFF position.