For comfortable use, How to operate ventilation – MITSUBISHI ELECTRIC PSA012B722 User Manual

Page 11

background image

10

7

Press

SET button (Fixing of the upper

limit position)

The upper limit position is fixed and the setting position is
displayed for two seconds. Then proceed to lower limit position
selection display.

[EXAMPLE]

” (lit for two seconds)

È

” (shows current setting)

8

Press

or button (Selection of lower limit

position)

Select the lower limit position of louver.
“position 1” is the most horizontal, and “position 6” is the most
downwards.
“position --” is to return to the factory setting. If you need to
change the setting to the factory setting, use “position --”.

” (the most horizontal)

⇔ “

⇔ “

⇔ “

⇔ “

⇔ “

” (the most downwards)

⇔ “

” (return to the position of shipment)

9

Press

SET button (Fixing of the lower limit

position)

Upper limit position and lower limit position are fixed, and the set
positions is displayed for two seconds, then setting is completed.
After the setting is completed, the louver which was set

moves from the original position to the lower limit position,
and goes back to the original position again. (This operation
is not performed if the indoor unit and/or indoor unit fan is in
operation.)

[Example]

” (lit for two seconds)

И

И

10

Press

button.

Louver adjusting mode ends and returns to the original display.

HOW TO SET THE AIR FLOW DIRECTION

< WIRED REMOTE CONTROL >

NOTICE

(downwards)

(horizontal)

the position of the louver

[EXAMPLE] For Upper position 2, Lower position 6

Lower
position

Movable
range

Upper
position

When plural remote controllers are connected, louver position setting cannot be set by slave remote control.

If you press

RESET button during settings, the display will return to previous display. If you press

button during settings, the mode will be ended and return to original display, and the settings that have not been

completed will become invalid.

Note : If the upper limit position number and the lower limit

position number are set to the same position, the louver
is fixed at that position. And auto swing does not function.

Clean the filter frequently

See page 14

If the filter is clogged…

The cooling/heating capacity will get reduced. Moreover it leads

to waste of electricity and larger operation noise.

It may cause failure.
Dew may form and drop during cooling.

Do not block the inlet and outlet grilles of the
indoor and outdoor units.

Excessive load to the unit may cause failure.

Keep moderate room temperature

Too much cooling or heating is not good for your health. It will also
waste the electricity.

Block direct sunlight and prevent draft

Block direct sunlight with blinds and curtains during cooling. Close
the windows and doors except when ventilation is necessary.

Adjust the airflow properly

Do not expose yourself directly to the airflow for too long time. For
small animals and plants, it is harmful as well.

If you feel cold underneath your feet during heating

If the ceiling is so high that the warm airflow does not circulate
underneath your feet, it is recommended to use a circulator.
Consult your dealer for more detail.

Stop the operation and turn the power supply
off if there are any possibility of lightning
strikes during a thunderstorm.

Lightning strikes may lead to the failure of air-conditioning system.

FOR COMFORTABLE USE

The filter should be cleaned when
the “Filter cleaning” message
is displayed, and at the end of
cooling and heating seasons.

HOW TO OPERATE VENTILATION

(WHEN A VENTILATOR IS INSTALLED) < WIRED REMOTE CONTROL >

1

Press

VENTI button.

” is displayed, and the ventilation operation begins.

Stop

Press

VENTI button again.

1

When the ventilator is set to “NO VENTI LINK”, the ventilator can be turned on and off independently regardless
of the operation of the air conditioner.
When the ventilator is set to “VENTI LINK”, the ventilator operation will be interlocked with the air conditioner
operation.

NOTICE

If no ventilator is connected, no operation can be performed by

pressing the ventilation button. (“

” is displayed).

VENTILATION OPERATION NOT LINKED WITH UNIT’S
OPERATION

1

Press

button.

If a ventilator is connected, ventilation will operate automatically.

” is displayed.

Stop

Press

button again.

NOTICE

No operation can be performed by pressing the ventilation button.

(“

” is displayed).

VENTILATION OPERATION LINKED WITH UNIT’S OPERATION