VENT INSTALLATION

This fi replace must be vented to the outside. The venting system must NEVER be
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.

W

ARNING

Horizontal sections of this vent system require
a minimum of 3" clearances to combustibles at
the top of the fl ue and 1" clearance at the sides
and bottom until the fl ue penetrates the outside
wall.
A minimum 1" clearance all around the fl ue
is acceptable at this point of penetration.

Vertical sections of this vent system require a
minimum of 1" clearance to combustibles on all
sides of the pipe.

Figure 7 - Combustible Clearances for Vent Pipe

A Minimum of 3" Clearance

to the Top Is Required Along

Horizontal Length until Flue

Pipe Penetrates Outside Wall.

W

ARNING

A Minimum 1"

Clearance to

Combustibles

Permitted All

Around Flue

at Outside

Wall