Warning clearances – Monessen Hearth Direct Vent Gas Fireplace BDV500 User Manual
Page 10

10
54D0700
12"
Maximum
Depth
11"Minimum
71"Minimum
Minimum 4"
From Both
Side Walls
Follow these instructions carefully to ensure safe installation. Failure to follow
in struc tions exactly can create a fi re hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood fl ooring. If installed on carpet or vinyl fl ooring, the appliance shall be installed
on a metal, wood or noncombustible material panel ex tend ing full width and depth of
the appliance.
W
ARNING
CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
3
/
4
" from the facing. If it does,
it is considered a mantel and must meet the mantel requirements listed in this manual.
Figure 6 - Clearances