beautypg.com

Boot cycle error codes, Operational check for the remote control, Optimizing the high-definition settings – Motorola DCT3412 User Manual

Page 35

background image

Installation 3-19

Boot Cycle Error Codes

If hardware or software problems occur, the terminal displays error codes on the LED display.
Table 3-2 lists error codes that can occur during boot cycle startup:

Table 3-2
Boot cycle error codes

Code

Description

When Error Occurs

Action Required

Eb 01

Object failed validation

After the LED displays dl, indicating
validation check failed

Contact headend
operator

Eb 02

Download time-out

After cycling twice through the OOB
frequencies

None

Eb 03

Flash erase failed

After software object download complete
and EF is displayed

Replace the terminal

Eb 04

Flash programming
failed

After software object download complete
and FP is displayed

Contact headend
operator

Eb 05

Invalid DLC frequency

After the LED displays dl, indicating
validation check failed

Contact headend
operator

Eb 06

Hardware initialization
failed

After plugging the terminal into an electrical
outlet to begin the boot cycle

Replace the terminal

Eb 07

Object failed validation

After software object download complete
and FP is displayed

After a successful software object
download and the terminal is reset

Contact the headend
operator

No action required
because the terminal
repeats the software
object download

Eb 08

Reserved

None

Eb 09

Check failed

Reset within two minutes of a complete
software object download

No action required
because the terminal
repeats software object
download process

Eb 10

SUDB recreation

After plugging the terminal into an electrical
outlet to begin the boot cycle

None

Eb 11

Failed to lock OOB
frequency

After cycling twice through the OOB
frequencies (LED then displays Eb 02,
indicating the software object download
was unsuccessful.)

Ensure proper cable
connections

Eb 12

No COAC message
received

After cycling twice through the OOB
frequencies (LED then displays Eb 02,
indicating the software object download
was unsuccessful.)

Contact headend
operator

Eb 13

No DLC message
received

After cycling twice through the OOB
frequencies (LED then displays Eb 02,
indicating the software object download
was unsuccessful.)

Contact headend
operator

Eb 14

Bad object type or class

After the LED displays dl, indicating failed

Contact headend

DCT3412 Installation Manual