Rdv4136 series direct vent gas fireplace, Locating your fireplace, Clearance to combustibles – Majestic Appliances RDV4136 User Manual

Page 6: Mantels

background image

6

RDV4136 Series Direct Vent Gas Fireplace

10010618

Y

E

A

B

C

D

F

Y

B

X

LU584-1

Locating unit

2/4/99 djt

A - Flat on wall

B - Cross corner

C - **Island

D - *Room divider E - *Flat on wall corner F - Chase installation

Y - 6” minimum

Note (Fig. 2):
** Island (C) and Room Divider (D) installation is possible as
long as the horizontal portion of the vent system (X) does not
exceed 20’ (6m). See details in manual Venting Section.
* When you install your fireplace in(D) Room divider or (E)
Flat on wall corner positions (Y), a minimum of 6” (152mm)
clearance must be maintained from the perpendicular wall and
the front side edge of the fireplace. See (Y) in Fig. 2.

Locating Your Fireplace

Fig. 2 Locate gas fireplace.

Top of Unit to Ceiling ............................... 36” (914 mm)

Appliance

Top .......................................................... 0” (0 mm)

Bottom ..................................................... 0” (0 mm)

Side ......................................................... 0” (0 mm)

Back ........................................................ 0” (0 mm)

Venting

Concentric sections of DV Vent

Top, bottom & sides .............................. 1” (25 mm)

Offset sections of DV Vent

Top ....................................................... 2” (51 mm)

Bottom & sides ...................................... 1” (25 mm)

Clearance to Combustibles

Fig. 3b Combustible mantel leg minimum installation.

CFM170

J

F

G

H

I

Mantel

Leg

CFM164a

Mantel Leg Chart

06/22/01 sta

Black

Surround

Face

CFM170

DV Builder Front

View

O

N

M

L

K

Side of

Combustion Chamber

Mantel

Mantel Leg FromSide

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10” (254 mm)

K

11¹⁄₂” (292 mm)

G

8” (203 mm)

L

9¹⁄₂” (241 mm)

H

6” (152 mm)

M

7¹⁄₂” (191 mm)

I

4” (101 mm)

N

5¹⁄₂” (140 mm)

J

2” (51 mm)

O

3¹⁄₂” (89 mm)

A B C D E

V

W

X

Y

Z

Fireplace

CFM146

DV Mantel Chart

7/5/01 sta

CFM146

Mantel Chart

Mantel Shelf

Mantel from Top

Ref.

or Breast Plate

Ref.

of Comb. Chamber

Depth

V

10” (254 mm)

A

19” (483 mm)

W

8” (203 mm)

B

17” (432 mm)

X

6” (152 mm)

C

15” (381 mm)

Y

4” (101 mm)

D

13” (330 mm)

Z

2” (51 mm)

E

11” (279 mm)

Fig. 3a Combustible mantel minimum installation.

Top of Combustion

Chamber

Standoff

Noncombstible Material

Framing Members

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 3a and 3b.
The fitting of a bay window trim kit does not effect
the distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.