0 wiring diagram, Connection logic, Warning – Maytag Ventilation Systems HRV-210 User Manual

Page 25

background image

25

9.0

Wiring Diagram

A1

M1

M2

K1

RELAY

K2

RELAY

K5

RELAY

FAN

MOTOR

DAMPER

MOTOR

NEUTRAL

MED

NC

HIGH

LOW

J1 6

J1 3

J1 4

J1 9

K4

RELAY

J3 1

J3 2

FURNACE BLOWER INTERLOCK

CLASS 2 CIRCUIT ONLY

ELECTRONIC ASSEMBLY

S1

120V 60Hz

FROM MAIN

J1 2

J1 1

J1 8

VE0018A

BK

G

R

Y

R

BK

Y

NOTE 4

WALL CONTROL

WALL CONTROL

WALL CONTROL

WALL CONTROL

OVERRIDE SWITCH

OVERRIDE SWITCH

OVERRIDE LED

FURNACE BLOWER

INTERLOCK

NOTES 1, 5

NOTE 5

OPTIONAL

NOTES 5, 6

OPTIONAL

M1

X2

M2

1

2

1

1

2

3

1

2

4

7

6

9

3

4

5

6

7

8

9

2

3

1

2

NEUTRAL

MEDIUM

HIGH

LOW

FAN MOTOR

X1

GY

O

G

BL

R

GY

O

G

NC

R

(NOTE 2)

BN

BN

C1

BL

BL

DAMPER

MOTOR

MAIN EARTHING

POINT

R

O

GY

W

T1

R1

A1

DEFROST

TEMPERATURE

SENSOR

JU1

J4

J1

J3

ABCDEFG

F

F

IO

CO

LY

RG

B

ELECTRONIC ASSEMBLY

Y

BL

BL

Y

COM

120V 60 Hz

W1

G

BK

W

NEMA-15P

5-15 PLUG

BK

DOOR INTERLOCK

SWITCH S1

NO

NEUTRAL

LINE

BK

VE0037A

-t

°

Models: ER

V

-150, HR

V

-150,

ER

V-210, HR

V-210

NOTES

1-

Controls available. See Section 8.0 (Low voltage only

, 12VDC)

2-

The factory set wiring for blower speed selection is high and low

.

Medium speed can be selected instead of low speed. Disconnect the

RED wire from the motor RED tap and connect it to the motor BLUE tap.

3-

If any of the original wire, as supplied, must be replaced, use the

same or equivalent wire.

4-

Use the factory supplied protective tubing.

5-

The field wiring must comply with applicable codes, ordonnances and

regulations.

6-

The furnace fan circuit must be class 2

circuit only

.

LINE VOL

TAGE

LOW VOL

TAGE

AND

FIELD WIRE

COLOR CODE

BK

BLACK

NC

NO CONNECTION

BL

BLUE

O

ORANGE

BN

BROWN

R

RED

G

GREEN

W

WHITE

GY

GREY

Y

YELLOW

DEFROST

TIME

JUMPERS T

ABLE

MODEL

MODEL

DEFROST/VENTILA

TION

TYPES MINUTES

23°F

5°F

-17°F

JU1A

JU1B

JU1C

JU1D

JU1E

JU1F

JU1G

-5°C

-15°C

-27°C

OUT

OUT

IN

IN

OUT

IN

OUT

HR

V

-150

6/32

6/32

6/20

HR

V

-210

OUT

IN

OUT

IN

OUT

IN

OUT

ER

V

-150

6/32

NOTE

NOTE

ER

V

-210

NO

NO

NO

NO

NO

OUT

NO

EXTENDED DEFROST

10/30

10/20

10/15

CHANGE

CHANGE

CHANGE

CHANGE

CHANGE

CHANGE

H

R

V

O

N

LY

Connection

Logic

A

B

C D E F G

2

1

JU 1

. .

. .

. .

. .

. .

. .

. .

FUNCTION

TABLE RELA

Y

MODE K1 K2 K4 K5

Intermittent 0

0 0

0

Exchange Low 1

0

1

1

Exchange High 1

1 1

1

Circulation Low 1

0

1

0

Circulation High 1

1 1

0

Defrost Cycle 1

1 1 0

O

ff 0

0

0

0

0 = Relay coil is de-energized

1 = Relay coil is energized

SPECIAL

DEFROST

CYCLE:

The mode is the same whichever t

h

e

exchange

speed selected by the wall control.

6 min. defrost 34 min. OFF 20 min. exchange low speed

BELOW

-1

5

°C

-

A

change of air exchange speed on the wall

control

(-

5

°F

)

during the special defrost cycle will reset the special

defrost cycle to the beginning (6 min. defrost).

-

The override circuit will remain active during the

special defrost cycle.

An override call will be answered.

-

If the outside temperature revert above -15°C (5°F),

it is only during the last part of the cycle (20 min.

exchange) that the controller will stop the special

defrost cycle.

NOTE

WARNING

010

!

Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the
unit from its power source.