0 technical data – Maytag Ventilation Systems HRV-210 User Manual
Page 11
11
Model numbers:
• ERV-150
• HRV-150
Model numbers:
• ERV-210
• HRV-210
13-3/4" (349mm)
20" (508mm)
(50
0"
6" (152mm)
2.5" (63mm)
30-1/4" (768mm)
VK0040
4.4
D
IMENSIONS
4.0
Technical Data
(cont’d)
19" (483mm)
20" (508mm)
08m
(50
6" (152mm)
30-1/4" (768mm)
2.5" (63mm)
VK0039
Main controls:
• Basic Wall Control
• Electronic Wall Control
Optional control:
• 20/40/60-minute push button
Link option:
• Furnace interlock (use with
forced air systems)
4.5
C
ONTROLS AND
F
URNACE
L
INK
O
PTION
4.6
S
PECIFICATIONS
Model numbers
Weight
Port Diameter
Drain Diameter
ERV-150, HRV-150
65 lb (30 kg)
6” (152 mm)
1/2” (12 mm)
ERV-210, HRV-210
73 lb (33 kg)
6” (152 mm)
1/2” (12 mm)
Installation
Chains, springs and hooks (provided with the unit).
Motor Speed
High and low speeds factory set (optional increased low speed - BLUE wire).
Electrical supply
120 V, 60 Hz
120 V, 60 Hz
Power Consumption
150 Watts
225 Watts