beautypg.com

0 typical installation – Maytag Ventilation Systems HRV-210 User Manual

Page 12

background image

12

5.0

Typical Installation

(Primarily for homes with radiant hot water or
electric baseboard heating. See figure 1.)

Moist, stale air is exhausted from the high
humidity areas in the home, such as bathrooms,
kitchen and laundry room. Fresh air is supplied
to bedrooms and principal living areas.

The use of bathroom fans and a range hood is
suggested to better exhaust stale air.

Homes with more than one level require at least
one exhaust register at the highest level.

5.1

F

ULLY

D

UCTED

S

YSTEM

There are three (3) common installation methods.

VH0024

figure 1

See 6.5.1
for details

5.2

E

XHAUST

D

UCTED

S

YSTEM

(S

OURCE

P

OINT

V

ENTILATION

)

(For homes with forced air heating. See figure 2.)

Moist, stale air is exhausted from the high
humidity areas in the home, such as bathrooms,
kitchen and laundry room. Fresh air is supplied
to the cold air return or the supply duct of the
furnace.

The use of bathroom fans and a range hood is
suggested to better exhaust stale air.

Homes with more than one level require at least
one exhaust register at the highest level.
NOTE: For this type of installation, it is not

essential that the furnace blower runs
when the unit is in operation, but we
recommend it.

VH0025

See 6.5.2
for details

figure 2

5.3

S

IMPLIFIED

(V

OLUME

V

ENTILATION

)

(For homes with forced air heating. See figure 3 or 4.)

Fresh air and exhaust air flow through the furnace ducts wich simplifies the installation.

The use of bathroom fans and a range hood is suggested to better exhaust stale air.

NOTE: For the installation type shown in figure 4, furnace blower should be running when the unit is

in operation.

VH0027

figure 3

See 6.5.3

VH0026

figure 4

See 6.5.3

OR

This manual is related to the following products: