beautypg.com

0 installation of the controls – Maytag Ventilation Systems HRV-210 User Manual

Page 23

background image

23

8.0

Installation of the Controls

(cont’d)

4- Connect the wires to the main control.

(See figure 17.)

5- Make sure the instruction pull-out is in the

occupant’s language. If not, turn it to the other side.
(See figure 18.)

6- Reinstall the cover plate and the button(s).

7- Connect the wires to their corresponding position inside the

electrical compartment. Make sure the connections of the unit
and of the wall control correspond exactly. (See figure 19.)

8- Connect the optional control (if applicable) by referring to Section 8.3.

9- Do the appropriate connection to the furnace (if applicable) by referring to Section 8.4.

10- NOTE: If the unit is installed in a cold region (Zone A, as defined in Section 3.0), set up “extended

defrost” by removing jumper JU1F on the main circuit board inside the electrical compartment

(see Section 9.0).

11- Plug in the unit and do the “overall verification” of the system as described in Section 11.0.

Y

R

GB

VD0026

F F I OC OL Y R G B

Y R G B

VE0072

VC0061

8.2 I

NSTALLATION OF THE

M

AIN

C

ONTROL (cont’d)

figure 17

figure 18

figure 19

This manual is related to the following products: