Portable gasoline generators, Standby installation to home or building, Generator grounding – Master Lock MGH8500IE User Manual

Page 8

background image

8

115407

PORTABLE GASOLINE GENERATORS

R

120

/240

V

TW

IST

LOC

K

120

/240

V

TW

IST

LOC

K

120

V

TW

IST

LOC

K

120

V

GFC

I

120

V

HO

UR

ME

TER

AUT

O-ID

LE

RES

ET

RES

ET

RES

ET

RES

ET

OFF

ON

RES

ET

TES

T

ENM

000

000

05

HO

UR

S

1/10

E

F

FUEL

STANDBY

INSTALLATION

TO HOME OR

BUILDING

WARNING: The electrician

must install a double-throw

transfer switch. This isolates ex-

isting electrical circuits from the

utility power line. If not isolated,

generator output will back-feed

into utility power line. This may

electrocute a power company line

repair person.

IMPORTANT: This generator will not

power your entire home. Most home utility

electric service is more than 60 amps. This

will exceed generator output. Only power

needed items during a power outage. Make

sure total wattage of electrical load does not

exceed rated wattage of generator.
You may need to use this generator as a

standby power source. During a power out-

age, the generator will power selected items

in a building. Have generator and additional

wiring installed by a skilled, licensed electri-

cian. This is not a do-it-yourself job. Follow

all local codes.

WARNING: Have standby in-

stallation performed by a skilled,

licensed electrician. Do not let

anyone else wire into a utility

circuit. Personal injury, equip-

ment damage, or damage to home

could occur.

GENERATOR

GROUNDING

Ground

Wire

Alternator

Copper or Brass

Grounding Point

Figure 11 - Grounding Generator

WARNING: For a grounding

point, do not use metal pipe be-

ing used to carry combustible

materials or gases.

Grounding generator helps prevent electric

shock from a ground fault condition. Follow

these steps to ground your generator:
1. Locate ground lug on generator housing

(see Figure 11).

2. Loosen set screw on ground lug. Note:

Do not remove set screw from ground

lug.

3. Push the bare end of a #10-8 stranded-

copper ground wire into ground lug.

Tighten set srew securely against ground

wire.

4. Drive grounding point into ground.

Note: Grounding point can be a stake,

grounding rod, or pipe. Grounding

point should be copper or brass.

6. Attach ground wire to grounding

point.

You must supply the ground wire and ground-

ing point. These do not come with generator.

Follow the National Electrical Code and all

state and local codes. Consult your power

company or a licensed electrician.

WARNING: You must prop-

erly earth-ground generator be-

fore starting. This will help guard

against deadly electric shock. Only

use grounded plugs with genera-

tor. Only use grounded extension

cords. Only use three-wire or

double-insulated power tools.

120

/240

V

TW

IST

LOC

K

120

V

TW

IST

LOC

K

120

V

VOL

TAG

E

HO

UR

ME

TER

AUT

O-ID

LE

RES

ET

RES

ET

RES

ET

RES

ET

OFF

ON

SEL

ECT

OR

120

ON

LY

120

+

240

ENM

000

000

05

HO

UR

S

1/1

0

E

F

FUEL

SEMS Nut

Flat Washer

Ground Bolt

Detail A

Spade Connector