Note: If oil level is too low, oil alert system

will keep engine from starting (see Oil Alert

System, page 5). Make sure oil level is full

before starting. See Engine Oil, page 6.
Before starting the engine, disconnect all

electric loads from generator.

STARTING

IMPORTANT: The engine speed is preset.

The throttle is locked in preset position. Do

not adjust throttle. Preset position lets engine

run at 3600 RPM under load. The engine

must maintain 3600 RPM for generator to

create correct voltage. Running engine at

lower speeds will damage generator and

powered items.
IMPORTANT: Never start generator with

electrical loads connected. Start engine

before adding electrical loads.
1. Make sure gasoline tank is full. See

Fuel, page 6 for fuel information.

2. Pull choke button out (see Figure 14).

This closes the choke.

Note: You may not need to close choke

if engine is warm or air temperature is

high.

WARNING: Only responsible

adults should use generator.

Never let anyone operate genera-

tor without proper instructions.

PRESTART

Operate generator on a firm, dry, and clean

surface. The surface must be level. Protect gen-

erator from heavy dust, sand, dirt, rain, or snow.

Do not locate generator near standing water and

snow. Make sure area is well-vented.

Continued

3. Start the engine.

Turn the engine switch to the START

position (see Figure 15). Hold it there

until engine starts. When engine starts,

let switch return to the ON position.

IMPORTANT: Do not use electric

starter more than five seconds. Starter

motor damage may occur. If engine

fails to start, release the switch and

wait ten seconds. After ten seconds, try

starting again.

Note: If engine does not start, check

the oil in the crankcase. Add oil as

necessary. Be sure engine is on a level

surface. See Oil Alert System, page 5.

4. As engine warms up, the choke will

automatically open.

Choke Button

Pulled Out

(Closed

Position)

Figure 14 - Choke Button Closed

HONDA

OFF

ON

START

ENGINE SW

CIRCUIT
BREAKER

ON/push OFF

Figure 15 - Engine Switch

Engine

Switch

120/2

40V

TWIS

TLOC

K

120/2

40V

TWIS

TLOC

K

120V

TWIS

TLOC

K

120V

GFCI

120V

HOU

R ME

TER

AUTO

-IDLE

RESE

T

RESE

T

RESE

T

RESE

T

OFF

ON

RE

SE

T

TE

ST

EN

M

00000005

HOURS 1/10

AUTO-IDLE OPERATION

IMPORTANT: Never start engine with elec-

trical loads connected. Start engine before

adding electrical loads.
1. If engine is cold, turn the Auto-Idle

switch OFF (see Figure 16).

2. Start engine. Allow engine to warm up

with no load for five minutes.

3. Turn Auto-Idle switch ON. Engine will

slow to idle speed. Engine idle speed

is preset. Idle speed adjustment should

not be necessary.

4. Operate generator according to speci-

fications outlined in owner’s manual.

5. Engine will automatically increase to

normal operating speed when you plug

load into any generator outlet.

6. The Auto-Idle system should be turned

OFF when generator is shut down.

Figure 16 - Control Panel

Auto-Idle Switch (Shown in ON Position)