beautypg.com

Owner’s manual, Generator features, Ground fault circuit interrupter receptacle – Master Lock MGH8500IE User Manual

Page 5: Oil alert system, Auto-idle system, Electric start

background image

5

115407

OWNER’S MANUAL

RESE

T

TEST

Figure 3 - GFCI Receptacle

2. If the GFCI receptacle tests okay,

restore power by pushing the RESET

button back in. The test lamp should

work at this time. IMPORTANT: You

must press the RESET button firmly

and fully. It should lock into place. If

the GFCI does not lock into place, do

not use receptacle. Contact a qualified

electrician for repairs.

GROUND FAULT CIRCUIT

INTERRUPTER RECEPTACLE

The GFCI receptacle is on the control panel.

The GFCI protects you against hazardous

electrical shock caused when your body

becomes a path through which electricity

travels to reach ground. This could happen

when you touch an appliance or cord that is

‘live’ through faulty mechanism, damp or

worn insulation, etc.
When protected by the GFCI, you may still

feel a shock, but the GFCI should cut it off

quickly. A person in normal health should

not receive serious injury. Note: Infants and

very small children may still be affected.

Test Procedure

Check the GFCI receptacle every month.

This insures it is working right.
1. Push TEST button. RESET button should

pop out. This should trip GFCI, result-

ing in no electrical power at receptacle.

Verify this by plugging test lamp with

good bulb into receptacle. If lamp does

not work, GFCI receptacle is good.

WARNING: If RESET button

does not pop out, do not use the

GFCI receptacle. Contact a quali-

fied electrician for repairs.

GENERATOR

FEATURES

OIL ALERT SYSTEM

The oil alert system protects the engine from

low oil damage. This system automatically

shuts down the engine and prevents engine

restarting if the oil level falls too low.
Note: When this happens, the engine switch

remains in the ON position. The oil alert

system is wired into the ON/OFF Switch.
If this system shuts down the engine, the

engine will not start until you add oil. Add

oil to engine (see Engine Oil, page 6).
Note: Operate generator on a level surface.

If not level, the oil may flow away from the

oil level sensing device. This will cause the

oil alert system to shut down engine.
See engine owner’s manual for more

information.

Figure 2 - Engine Switch Location

AUTO-IDLE SYSTEM

The Auto-Idle System allows the engine to idle

down or run at a slower speed when the gen-

erator is not being used to supply power. The

Auto-idle system can be turned ON or OFF by

a rocker switch on the control panel. When the

switch is in the OFF position, the engine runs

at full speed all of the time. When the switch

is in the ON position, the engine slows down

to idle speed until an electrical load is applied.

When a load is applied to the generator (an

electrical item is plugged in and turned on) the

engine speeds up to the preset speed required

to produce the correct voltage.
IMPORTANT: A minimum current load

of 1 Amp is required to disengage the auto

idle solenoid and cause the engine to come

up to speed for correct voltage. Powering

items at reduced engine speed will damage

generator and powered items.

HONDA

OFF

ON

START

ENGINE SW

CIRCUIT
BREAKER

ON/push OFF

ELECTRIC START

A battery is not supplied with generator.

You must provide a 12-volt, 32-amp-hour

battery. For more battery information, see

Battery, page 7.

Engine Switch