Maintenance

Section 4

4-8

Part Number 80-1561-3

Water Level Probe

1. Remove the water trough.

2. The water level probe normally does not require

removal for cleaning. The probe can be wiped and
cleaned in place or proceed to step 3.

3. Pull the water level probe straight down to

disengage.

4. Lower the water level probe until the wiring

connector is visible. Disconnect the wire lead from
the water level probe.

5. Remove the water level probe from the ice machine.

Water Pump

1. Empty the water trough.

A. Move the toggle switch from OFF to ICE.

B. Wait 45 seconds.

C. Place toggle switch in OFF position.

Water Pump Removal

2. Remove the water trough.

3. The water pump normally does not required removal

for cleaning. The water pump base can be wiped
and cleaned in place or proceed to step 4.

4. Grasp pump and pull straight down on pump

assembly until water pump disengages and
electrical connector is visible.

5. Disconnect the electrical connector.

6. Remove the water pump assembly from ice

machine.

7. Do not soak the water pump in cleaner or sanitizer.

Wipe the pump and ice machine base clean.

!

Warning

Disconnect the electrical power to the ice machine
at the electrical disconnect before proceeding.

SV3141

WATER LEVEL PROBE

!

Warning

Disconnect the electric power to the ice machine at
the electric service switch box and turn off the water
supply before proceeding.

SV3091

WATER

PUMP