Alarm pan-tilt control network motion detection, Digital video recorder – Mace DVR1604RW User Manual
Page 34

DVR1604RW
Digital Video Recorder
Operational Manual
© 2004 Mace Security Products.
34
Select the relevant Camera in CH (this recorder has 8-Ch alarm input). TYPE has NO
(normal open) NC (normal close) output modes. If the Camera number in RECORD
is selected, recording would be started for that Camera automatically when there is alarm
input. If the alarm output port is chosen, it will trigger the corresponding relay when
there is an alarm input. DELAY means to extend the recording time after receiving alarm
signal clears.10, 20, 30
90SEC delays. When the outside alarm is cleared, the
system will extend the recording time automatically before closing alarm and relay
output. When Time 1 or Time 2 are on, if an alarm occurs within the time of these
settings, the recording will be triggered by alarm signals. The beginning time should be
earlier than the ending time. The setting in Time 2 should be later than the setting in
Time 1. ALMSVR IP is used to transmit the alarm signals to the designated IP server.
Select the corresponding channel in CH , and choose the protocol of the
brand name of the corresponding pan-tilt decoder in PROTOCOL.
ADDR is the address of the corresponding PTZ Camera.
IP is set by using pq or input the exact numbers to change the IP address. IP
address setting can only be here. The related SUBNETMASK and GATEWAY
should be set according to the IP address. MONITOR and PLAYBACK can be changed
by using pqTCP/IP or MULTICAST. Save the setting in SAVE, and restart the recorder.
Note: MULTICAST: The users with Admin levels can monitor each channel freely. All other
users can only view after Admin releases camera. 5 users at maximum.
TCP Protocol: All users are able to monitor any channel. User shall select Camera # desired. If the
transmission is over Internet, TCP should be chosen. 2 users can log in at a maximum.
Select the Camera channel in CH . Open or close (On/Off) the function in
STATE. Choose how long you want to continue the recording (10, 20,
30, ……90SEC) when motion is detected and then cleared. ALMOUT controls the
alarming state for motion detection. SENS has three levels: LOW, MID, HIGH. AREA
can be accessed by pressing ENTER. The setting area can be divided in 192 sections.
Red section means the current cursor position, and the blue section is the motion
detection area. Areas with no color are no motion detection areas. Press Fn to locate
the current section, then move the cursor to cover the MD area needed; press Fn again
to choose the MD area. Press pq to get the setting and press ENTER to confirm.
Alarm
Pan-tilt control
Network
Motion detection
C H 0
TYPE NORAML OPEN
No 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6
OUTPUT
RECORD
TIM E1
00
00
24
00
ON
TIM E2
00
00
24
00
OFF
PRE-RECORD
OFF
TIP OFF
DEFAULT
SAVE
CANCEL
CH
1
PROTOCOL
NONE
ADDRESS
008
BAUDRATE
4800
DATA BIT 8 BIT
STOP BIT 1 BIT
VERIFY NULL
DEFAULT SAVE CANCEL
CH
0
No 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 16
ALMOUT
RECORD
D E L A Y 3 0 SEC T I P S O F F
P R E C O R D O N
L E V E L H I G H
AREA
SET
TIME1 10:00AM— 02:00PM
OFF
TIME2 10:00AM— 02:00PM
OFF
DEFAULT SAVE CANCEL