beautypg.com

Troubleshooting guide – Metrologic Instruments MS6200 User Manual

Page 18

background image

14

T

ROUBLESHOOTING

G

UIDE

The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited
warranty terms on page 28.

S

YMPTOMS

P

OSSIBLE

C

AUSE

(

S

)

S

OLUTION

No LEDs, beep
or laser line

No power is being supplied to
the scanner

Check transformer,
outlet and power strip.
Make sure the cable is
plugged into the
scanner.

No LEDs, beep

No power is being supplied to
the scanner from host

Some host systems
cannot supply enough
current to power the
MS6220. Use the
proper power supply.

3 beeps on
power up

Non-volatile RAM failure

Contact a Metrologic
Representative, if the
unit will not hold the
programmed
configuration.

Continuous razz
tone on power up

RAM or ROM failure

Contact a Metrologic
Representative.

Razz tone at
power up

VLD failure or a Scanner
flipper failure

Contact a Metrologic
Representative.

Unit scans,
Communicates
and beeps twice

Same Symbol timeout set too
short

Adjust same symbol time
out for a longer time.

The unit powers
up but does not
beep

Beeper disabled. No tone
selected

Enable beeper. Select
tone.