GENERATOR START-UP PROCEDURE

BEFORE STARTING

1. Place

the

main, G.F.C.I., and aux. circuit breakers (Figure

36) in the OFF position prior to starting the engine.

Figure 36. Main, Aux. and GFCI

Circuit Breakers (OFF)

2. Make sure the voltage change-over board has been

confi gured for the desired output voltage.

3. Connect the load to the receptacles or the output

terminal lugs as shown in Figure 11. These load
connection points can be found on the output terminal
panel and the output terminal panel’s hard wire hookup
panel.

4. Tighten terminal nuts securely to prevent load wires

from slipping out.

5. Close all engine enclosure doors (Figure 37).

Figure 37. Engine Enclosure Doors

CAUTION

The engine’s exhaust contains harmful emissions.
ALWAYS have adequate ventilation when operating.
Direct exhaust away from nearby personnel.

WARNING

NEVER manually start the engine with the main, GFCI or
auxiliary
circuit breakers in the ON (closed) position.

INCORRECT

CORRECT

STARTING

1. Place

the voltage selector switch in the desired

voltage position (Figure 38).

Figure 38. Voltage Selector Switch

STARTING (MANUAL)

1. Place the engine speed switch (Figure 39) in the LOW

(down) position.

Figure 39. Engine Speed Switch (Low)

2. Place

the

MPEC control switch in the MANUAL

position to start the engine (Figure 40).

Figure 40. MPEC Control Switch

(Manual Position)

3. Depending on the temperature of the coolant (cold

weather conditions), the pre-heat lamp (Figure 41) will
light (ON) and remain on until the pre-heating cycle has
been completed. After completion of the pre-heating
cycle, the light will go OFF and the engine will start up
automatically.

Figure 41. Pre-Heat Lamp

4. Once the engine starts, let the engine run for 1-2

minutes. Listen for any abnormal noises. If any
abnormalities exist, shut down the engine and correct