beautypg.com

Dual cable scale configuration bar codes, Com port settings (data bits & parity) – Metrologic Instruments Stratos MS2x20 Series User Manual

Page 25

background image

20

S

CALE

C

ONFIGURATION

B

AR

C

ODES

Dual Cable Scale Configuration Bar Codes

COM Port Settings (Data Bits & Parity)

The following bar codes will change scale parameters intended for a
Dual Cable environment.

If a Scale Protocol bar code from page 12 to 17 is used, the bar codes
below must be scanned after the Scale Protocol bar code in order to be
effective.

If the MS2

xx0 is currently in a Dual Cable configuration, temporarily

disconnect the Scale to Host cable prior to configuring the scale.

The MS2

xx0 does not need to be in scale service mode.

The Scale Save Data bar code must be scanned last to save the
changed configuration (see page 2).

Scale = 7 Data Bits,

Odd Parity

³

9

9

6

0

2

1

Set the scale communication parameters to
7 data bits, odd parity.

Scale = 7 Data Bits,

Even Parity

³

9

9

6

0

2

2

Set the scale communication parameters to
7 data bits, even parity.