beautypg.com

Motorola F5217A User Manual

Page 10

background image

10 MW800 Owner’s Manual


If the system does not respond, you can turn the device off by pressing and holding
the display power button for 6 seconds or more. To permit this option, Critical turn
off
parameter (see Section 3) setting should be ENABLE. Be aware, this hardware
power off may damage your hard disk.

Extreme Shut Down

Some extreme events might cause the device to power off. These are ambient
temperature below the low or above the high operating limit or discharged car
battery.

Internal temperature is beyond the operational limit.

If during operation the internal temperature goes out of the low operational
limits, the display eventually powers off.


Vehicle battery is discharged.

If, during normal operation, the battery voltage drops below 10.5VDC the
display will provide Low Battery indication (the power indicator blinks
yellow). If the voltage continues to drop, the device automatically powers off
at 8.5VDC.

Drops in car battery voltage.

If battery voltage drops below the 8.8V limit for 20 seconds or more, the
device will execute critical shut off and power itself off.

Power Management

This chapter describes how to enter the CPU into low-power mode (standby) and
resume normal operating mode.

Standby

The display can enter the CPU into low-power state by pressing the Standby button
on the right display’s side.

One more way to move the CPU into low-power mode is to configure the Power
button to enter the CPU into a low-power state. For details about this option, refer to
the help file attached to Power Options (Start -> Settings -> Control Panel ->
Power Options
).

Resume

The display can resume the CPU using the following methods:

• A contact to the touch panel of the MW800 display