beautypg.com

Portable forced air heaters, Service procedures – Master Lock B150CEA User Manual

Page 8

background image

8

104468

PORTABLE FORCED AIR HEATERS

R

Figure 9 - Fuel Filter Removal, 35/70,000 Btu/Hr Models

Fuel Filter

Side Cover

Fuel Line

Fuel Filter, Bushing, and
Lower Fuel Line

Side Cover

Upper
Fuel
Line

Figure 10 - Fuel Filter Removal, 100/150,000 Btu/Hr Models

SERVICE
PROCEDURES

Upper Shell Removal

1.

Remove screws and lock washers along
each side of heater using 5/16" nut-
driver. These screws attach upper and
lower shells together.

2.

Lift upper shell off.

3.

Remove fan guard.

Fuel Filter

(35/70,000 Btu/Hr Models)

1.

Remove side cover screws using 5/16"
nut-driver.

2.

Remove side cover.

3.

Pull rubber fuel line off fuel filter neck.

4.

Carefully pry bushing and fuel filter out
of fuel tank.

5.

Wash fuel filter with clean fuel and re-
place in tank.

6.

Attach rubber fuel line to fuel filter
neck.

7.

Replace side cover.

Fuel Filter

(100/150,000 Btu/Hr Models)

1.

Remove side cover screws using 5/16"
nut-driver.

2.

Remove side cover.

3.

Pull upper fuel line off fuel filter neck.

4.

Carefully pry bushing, lower fuel line,
and fuel filter out of fuel tank.

5.

Wash fuel filter with clean fuel and re-
place in tank.

6.

Attach upper fuel line to fuel filter neck.

7.

Replace side cover.

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

Upper Shell

Fan Guard

Fan
Guard

Upper
Shell

Figure 7 - Upper Shell Removal, 35/70,000
Btu/Hr Models

Figure 8 - Upper Shell Removal, 100/
150,000 Btu/Hr Models

This manual is related to the following products: