Version “17” Pin Assignments for Keyboard Wedge, RS-232 and
Light Pen Emulation

The version “17” scanner head cable is terminated with a male 25-pin D-type
connector. Connecting the scanner to a PC, requires a communication cable and
a transformer. Connecting the communication cable to a PC, may require an
adaptor cable. This can be ordered when the scanner is purchased.

The version “17” scanner is designed to be used as a keyboard wedge. However,
with the appropriate communication cable, the scanner will also provide an RS-
232 or light pen emulation interface. When configuring the scanner for one
interface versus another, change all necessary parameters for that particular
interface. For instance, when configuring the scanner for keyboard wedge
emulation, recall defaults, select the PC type, keyboard country type and
intercharacter delay. For further information, refer to the ScanSelect Scanner
Programming Guide or ScanSet Scanner Configuration Guide.

The following is a list of the pin assignments. The pin numbers are impressed on
the head cable’s connector.

Pin

Function

Pin

Function

1

AC Shield Ground

14

Power Ground 1

2

RS-232 Receive Input

15

Light Pen Source

3

RS-232 Transmit Output

16

Light Pen Data

4

CTS Input

17

PC Data

5

RTS Output

18

PC Clock

6

Reserved

19

Power (11 - 30 volts) DC

7

Signal Ground

20

DTR Input

8 - 10

Reserved

21

Keyboard Clock

11

PC +5 Volts DC

22

Keyboard Data

12

Ground

23 - 24

Reserved

13

Earth Ground

25

Power Ground 2