Metrologic Instruments MS860 User Manual
Page 43
39
Version “17” Pin Assignments for Keyboard Wedge, RS-232 and
Light Pen Emulation
The version “17” scanner head cable is terminated with a male 25-pin D-type
connector. Connecting the scanner to a PC, requires a communication cable and
a transformer. Connecting the communication cable to a PC, may require an
adaptor cable. This can be ordered when the scanner is purchased.
The version “17” scanner is designed to be used as a keyboard wedge. However,
with the appropriate communication cable, the scanner will also provide an RS-
232 or light pen emulation interface. When configuring the scanner for one
interface versus another, change all necessary parameters for that particular
interface. For instance, when configuring the scanner for keyboard wedge
emulation, recall defaults, select the PC type, keyboard country type and
intercharacter delay. For further information, refer to the ScanSelect Scanner
Programming Guide or ScanSet Scanner Configuration Guide.
The following is a list of the pin assignments. The pin numbers are impressed on
the head cable’s connector.
Pin
Function
Pin
Function
1
AC Shield Ground
14
Power Ground 1
2
RS-232 Receive Input
15
Light Pen Source
3
RS-232 Transmit Output
16
Light Pen Data
4
CTS Input
17
PC Data
5
RTS Output
18
PC Clock
6
Reserved
19
Power (11 - 30 volts) DC
7
Signal Ground
20
DTR Input
8 - 10
Reserved
21
Keyboard Clock
11
PC +5 Volts DC
22
Keyboard Data
12
Ground
23 - 24
Reserved
13
Earth Ground
25
Power Ground 2