beautypg.com

Monessen Hearth MHSC EYF24 User Manual

Page 28

background image

28

65D1009

OPERATING INSTRUCTIONS

MILLIVOLT CONTROL LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo

ignitor does not light the pilot, see instructions for Match Lighting Instructions, page 29.

4. Turn gas control knob clockwise

to the OFF position. Turn ON/OFF switch to OFF position.

5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!

Follow "B" in the safety information label. If you don't smell gas, go to next step.

6. From OFF position, turn the gas control knob counterclockwise

to IGN position. Push in control

knob for 5 seconds.

7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off

the gas while the probe is warming up. Release the control knob.

9. Turn gas control knob counterclockwise

to the ON position.

10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON

position.

11. If the gas logs will not operate, follow the instructions To Turn Off Gas To Appliance below and call your

service technician or gas supplier.

TO TURN OFF HEATER

1. Turn control knob clockwise

to OFF position to completely shut off the heater.

2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.

Figure 39 - Pilot

Figure 40 - Control Cover Plate for Millivolt

Hi/Lo Control

On/Off/Pilot Control

On/Off Switch

Piezo

This manual is related to the following products: