16"

42"

CLEARANCES

AND

HEIGHT REQUIREMENTS

Sidewall and ceiling clearances: The sides of the fireplace opening must be at least 16" from any combustible wall.
The ceiling must be at least 42" from the top of the fireplace opening.

Figure 4 - Sidewall and Ceiling Clearances

WARNING

The dimensions shown in Figures 4 through 10 and defined in the fireplace
manufacturer's instructions are minimum clearances to maintain when installing this
heater. Left and right clearances are determined when facing the front of the heater.
When heater is installed into a ventless firebox, minimum clearances, as specified by
the ventless firebox manufacturer, must be met.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.