FLOOR CLEARANCE

The gas log heater must be installed at least 5" above any combustible flooring material, such as carpeting or tile, which is
closer than 14" to the base of the fireplace. The minimum distance must be maintained from the top surface of carpeting,
tile, etc. See Figure 9.

OR,

The gas log heater may be installed nearer to the floor if a minimum of 14" of noncombustible material such as slate or marble
is installed between the base of the fireplace and the combustible flooring. See Figure 10.

Figure 9 - Minimum Clearance above Combustible Flooring

Figure 10 - Minimum Clearance above Combustible Flooring with

Noncombustible Material Installed at Base of Fireplace