Name

Description

Module set to address

Comfort lighting

Reacts to the Lights ON and Lights OFF button on your key chain
remote control.

C1 and C2

Exit delay

Lights are switched on during the exit delay.

C1 and C2

Alarm lighting

In the case of an alarm, the lights will flash during 4 minutes and
then remain on.

C1 and C2

Status indicator

The lights are switched on when the system is set to ARM AWAY.

D1

External Siren PH7208

Extra 110dB siren.

C1 or C2

Extra universal siren

Connect your own siren to a Marmitek AM12 or AD10 module.

D2

To change the HouseCode:
1. To access the menu, press the menu

or menu

button. The display will now read ‘ENTER PIN’.

2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). For every digit entered, a * will appear
on the display.
3. When the PIN code has been entered correctly, the word ‘INSTALL’ will show up on the display.
4. Use the menu buttons /

to go to menu item 7. OPTIONS. Press OK to select this menu item. You can also go to this menu

item directly by pressing a 7 on the number pad.
5. Use the menu buttons /

to go to menu item HOUSECODE. Press OK to select this menu item.

6. Use the menu buttons /

to select the desired HouseCode and press OK.

7. Press CLEAR again to quit the menu.

Did you already have several Marmitek X-10 modules installed before installing the security system? Then you may need to change
the basic UnitCode for the system. This means you do not need to change the addresses of the existing system.

If you change the UnitCode of the console, the addresses for the Home Automation functions also change. Example: You change
the UnitCode from 1 into 5:

Name

Description

Module set to address

Comfort lighting

Reacts to the Lights ON and Lights OFF button on your key chain
remote control.

A5 and A6

Exit delay

Lights are switched on during the exit delay.

A5 and A6

Alarm lighting

In the case of an alarm, the lights will flash during 4 minutes
and then remain on.

A5 and A6

Status indicator

The lights are switched on when the system is set to ARM AWAY.

B5

External Siren PH7208

Extra 110dB siren.

A5 or A6

Extra universal siren

Connect your own siren to a Marmitek AM12 or AD10 module.

B6

EXTRA OPTIONS

32

MARMITEK

20071_20070228_UG_SC9000_EN 08-03-2007 10:07 Pagina 32