beautypg.com

Cutting fluid system, Notice – Grizzly G0717 User Manual

Page 36

background image

-34-

Model g0717 (Mfg. since 9/10)

Cutting fluid system

fiRE hazaRD! DO nOt

cut magnesium when

using oil-water solutions

as a cutting fluid! always

use a cutting fluid intend-

ed for magnesium. the

water in the solution will

cause a magnesium-chip

fire.

this bandsaw has a built-in cutting fluid system
that extends the life of your bandsaw blades
by lowering the temperature of the blade and
workpiece when cutting.

see

Cutting fluid on page 33 for additional

information.

to use the cutting fluid system:

1. access the reservoir by removing the rear

panel on the base (see

figure 39).

figure 39. Cutting fluid system reservoir cover.

figure 40. Coolant control valve.

Coolant

Control

Valve

NOTICE

Keep the tray chip screen clear so cutting
fluid

can recycle to the pump reservoir.

nEvER operate the pump with the reservoir

below the low mark or you will overheat the

pump and void your warranty!

2. thoroughly clean and remove any foreign

material that may have fallen inside the res-
ervoir during shipping.

3. Fill the reservoir with your chosen cutting fluid

solution and replace the rear panel.

4. Make sure the cutting fluid control valve is

turned

OFF.

5. turn the cutting fluid pump switch ON before

making your cut.

6. adjust the valve on the coolant hose to con-

trol the flow of cutting fluid (see

figure 40).

Make sure that the pressure is not so high
that cutting fluid spills on the floor and creates
a slipping hazard.

7. When the bandsaw reaches the bottom of the

cut, the motor and cutting fluid system will
shut

OFF.

reservoir Cover