Cutting fluid system, Notice – Grizzly G0717 User Manual
Page 36
-34-
Model g0717 (Mfg. since 9/10)
Cutting fluid system
fiRE hazaRD! DO nOt
cut magnesium when
using oil-water solutions
as a cutting fluid! always
use a cutting fluid intend-
ed for magnesium. the
water in the solution will
cause a magnesium-chip
fire.
this bandsaw has a built-in cutting fluid system
that extends the life of your bandsaw blades
by lowering the temperature of the blade and
workpiece when cutting.
see
Cutting fluid on page 33 for additional
information.
to use the cutting fluid system:
1. access the reservoir by removing the rear
panel on the base (see
figure 39).
figure 39. Cutting fluid system reservoir cover.
figure 40. Coolant control valve.
Coolant
Control
Valve
NOTICE
Keep the tray chip screen clear so cutting
fluid
can recycle to the pump reservoir.
nEvER operate the pump with the reservoir
below the low mark or you will overheat the
pump and void your warranty!
2. thoroughly clean and remove any foreign
material that may have fallen inside the res-
ervoir during shipping.
3. Fill the reservoir with your chosen cutting fluid
solution and replace the rear panel.
4. Make sure the cutting fluid control valve is
turned
OFF.
5. turn the cutting fluid pump switch ON before
making your cut.
6. adjust the valve on the coolant hose to con-
trol the flow of cutting fluid (see
figure 40).
Make sure that the pressure is not so high
that cutting fluid spills on the floor and creates
a slipping hazard.
7. When the bandsaw reaches the bottom of the
cut, the motor and cutting fluid system will
shut
OFF.
reservoir Cover