110 vac, Bf c c d – Grizzly G0717 User Manual
Page 19
Model g0717 (Mfg. since 9/10)
-17-
11. open the motor junction box, loosen the ter-
minal screws indicated in
figure 14, feed the
cord through the strain relief on the junction
box, then connect the wires as shown.
12. Make sure all wiring connections are secure,
tighten the strain relief on the motor junction
box to prevent the cord from being acciden-
tally pulled out, then replace the motor junc-
tion box cover.
13. remove the two hex bolts shown in figure
15.
14. slide the pulley cover behind the motor pulley
first, then the gearbox pulley. Mount it using
the hardware removed in
step 13, as shown
in
figure 16.
Start
Capacitor
400MFD
125VAC
Run
Capacitor
40MFD
250VAC
Hot
Ground
Hot
Cutting Fluid
Pump Motor
1/8HP, 220V
Control Panel
(viewed from behind)
Main Motor 1-1/2HP, 220V
Saw Travel
Limit Switch
6-15 Plug
(Included)
220
VAC
G
Ground
Start
Capacitor
3MFD
450VAC
Ground
1
2
4
4
1
1
1
1
5
5
3
3
3
3
2
4
4 0
1
2
1
3
2
2
2
2
V1
V1
U1
U1
V2
U2
4
1
3
2
Cutting Fluid
Pump Switch
Emergency Stop Button
Start Button
ON Lamp
b
b
f
c
c
d
Cutting Fluid
Pump Motor
Rewired for 110V
Ground
Start
Capacitor
3MFD
450VAC
V2
U2
4
1
3 2
e
Run
Capacitor
40MFD
250VAC
Main Motor, Rewired for 110V
Ground
4
1
3
2
V1
V1
U1
U1
Rewired for 110V
Rewired for 110V
d
e
Neutral
Hot
Ground
110 VAC
5-20 Plug
(As Recommended
for 110V)
Rewired for 110V
f
figure 14.
Wiring motor.
figure 16.
Mounting belt cover.
loosen these
terminals
strain
relief
figure 15.
Belt cover hardware.
hex Bolts & Washers
hex Bolts &
Washers
Belt