Force Timer

If selecting “Yes” the phone will use session timer even if the remote party does not support 
this feature. Selecting “No” will allow the phone to enable session timer only when the remote 

party support this feature.   To turn off Session Timer, select “No” for Caller Request Timer, 
Callee Request Timer, and Force Timer.

UAC Specify 
Refresher

As a Caller, select UAC to use the phone as the refresher, or UAS to use the Callee or proxy 
server as the refresher. 

UAS Specify 
Refresher

As a Callee, select UAC to use caller or proxy server as the refresher, or UAS to use the 
phone as the refresher.

Force INVITE

Session Timer can be refreshed using INVITE method or UPDATE method. Select “Yes” to 
use INVITE method to refresh the session timer. 

Enable 100rel

The use of the PRACK (Provisional Acknowledgement) method enables reliability to be offered 
to SIP provisional responses (1xx series). This is very important if PSTN inter­networking is to 

be supported. A user’s request to use reliable provisional responses is invoked by the 100rel 
tag which is appended to the value of the required header of initial signalling messages.

Refer­to uses 
Target Contact

Default is NO. If set to YES, then for Attended Transfer, the “Refer­To” header uses the 
transferred target’s Contact header information.  

INVITE Ring­no­
answer Timeout

In case incoming call has arrived from PSTN to VoIP and INVITE message was generated by 
GXW device, the call will be disconnected after pre­configured timeout if not answered by VoIP 

extension.

Preferred Vocoder The GXW410x supports up to 5 different Vocoder types including G.711 A­/U­law, GSM, 

G.723.1, G.729A/B.  The user can configure Vocoders in a preference list that will be included 
with the same preference order in SDP message. The first Vocoder in this list can be entered 

by choosing the appropriate option in “Choice 1”. Similarly, the last Vocoder in this list can be 
entered by choosing the appropriate option in “Choice 8”. 

Special Feature

Default is Standard. Choose the selection to meet some special requirements from Soft Switch 
vendors like Nortel, Broadsoft, etc. 

S

AVING

 

THE

 C

ONFIGURATION

 C

HANGES

When changes are  made, press the “Update” button in  the  Configuration  Menu. The  GXW410x will 
display the following screen to confirm that the changes have been saved.  To activate changes, reboot 
or power cycle the GXW410x after all changes are made.  

R

EBOOTING

 

FROM

 R

EMOTE

The administrator can remotely reboot the unit by pressing the “Reboot” button at the bottom of the 
configuration menu. The following screen will indicate that rebooting is underway.

The user can re­login to the unit after waiting for about 30 seconds.