STUN Server

IP address or Domain name of the STUN (Simple Traversal of UDP through NATs) server. 

Firmware 
Upgrade & 
Provisioning

This radio button will enable GXW410x to download firmware or configuration file through either 
TFTP or HTTP.

Via TFTP Server If selected, the GXW410x will attempt to retrieve new configuration file or new code image from the 

specified TFTP server at boot time. It will make up to 5 attempts before timeout and then it will start 

the   boot   process   using   the   existing   code   image   in   the   Flash   memory.   If   a   TFTP   server   is 
configured and a new code image is retrieved, the new downloaded image will be verified and then 

saved into the Flash memory.

Note: Please do NOT interrupt the TFTP upgrade process (especially the power supply) as this will 
damage the device.  Depending on the network environment this process can take up to 25 or 30 

minutes.

Via HTTP Server The URL for the HTTP server used for firmware upgrade and configuration via HTTP.  

For example, http://provisioning.mycompany.com:6688/Grandstream/
Here “:6688” is the specific TCP port that the HTTP server is listening at, it can be omitted if using 

default port 80.

Note: If Auto Upgrade is set to No, GXW410x will only do HTTP download once at boot up.

Firmware Server 
Path

IP address or domain name of firmware server.

Config Server 
Path

IP address or domain name of configuration server.

Firmware File 
Prefix

Default is blank.  If configured, GXW400X will request firmware file with the prefix.  This setting is 

useful for ITSPs.  End­user should keep it blank. 

Firmware File 
Postfix

Default is blank.  End­user should keep it blank.

Config File 
Prefix

Default is blank.  End­user should keep it blank.

Config File 
Postfix

Default is blank.  End­user should keep it blank.

Allow DHCP 
Option 66 to 
override server

Default value is No. If set to Yes, configuration file will originate from the DHCP server.

Automatic 
Upgrade

Choose  Yes  to enable automatic upgrade and provisioning.   In “Check for new firmware every” 

field, enter the number of minutes to enable GXW410x to check the server for firmware upgrade or 
configuration.  When set to 

No, GXW410x will only do upgrade once at boot up. Other options are: 

“ Always check for New Firmware.” 
“ Check New Firmware only when F/W pre/suffix changes”
“ Always skip the Firmware check”

Authenticate 
Conf File

If set to Yes, configuration file is authenticated before acceptance. This protects the configuration 