Power connection – Grizzly G0596-99 User Manual
Page 9

model g0596-99 (mfg. since 3/06)
-7-
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro-
cess. DO NOT connect the machine to the
power source until instructed to do so.
power Connection
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
the motor for your machine may draw the follow-
ing amps at maximum load.
g0596 at 110V single-phase ............... 14 Amps
g0597 at 220V single-phase .............. 8.5 Amps
g0598 at 220V single-phase ............... 12 Amps
g0599 at 220V 3-phase ....................... 10 Amps
power Supply Circuit Requirements
the power supply circuit for your machine mUst
be grounded and rated for the amperage given
below. Never replace a circuit breaker on an exist-
ing circuit with one of higher amperage without
consulting a qualified electrician to ensure compli-
ance with wiring codes.
If you are unsure about
the wiring codes in your area or you plan to
connect your machine to a shared circuit, con-
sult a qualified electrician.
g0596 power source ........... 110V single-phase
g0596 minimum Circuit size ................ 20 Amps
g0597 power source ...........220V single-phase
g0597 minimum Circuit size ................ 15 Amps
g0598 power source ...........220V single-phase
g0598 minimum Circuit size ................ 15 Amps
g0599 power source ...................220V 3-phase
g0599 minimum Circuit size ................ 15 Amps
figure 1. NEmA 6-15 plug and receptacle.
figure 2. NEmA 15-15r plug and receptacle.
plug Type
With the exception of the g0596, the cord set
enclosed does not have a plug as the style of plug
you require will depend upon the type of service
you currently have or plan to install. We recom-
mend using the following plugs for your machine
on a dedicated circuit only (see
figures 1–?? for
examples):
g0597 at 220V ......................... NEmA 6-15 plug
g0598 at 220V ......................... NEmA 6-15 plug
g0599 at 220V 3-phase .. NEmA 15-15r plug or
..220V locking shut-off switch (recommended)