beautypg.com

110v operation – Grizzly H6246 User Manual

Page 10

background image

-8-

H6246 Meat Cutting Bandsaw

Figure 2. A 5-15 plug and receptacle.

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110V Operation

Amperage Draw

The

3

/

4

HP motor on the Model H6246 will draw

the following amps:

Motor Load ..............................................5 Amps

Circuit Breaker Requirements

Install your machine on a dedicated circuit to
reduce the possibility of tripping the circuit break-
er. If the circuit breaker frequently trips, have the
circuit inspected by a qualified electrician. Never
use a larger circuit breaker than stated below, or
you will increase the risk of fire.

Circuit Breaker .........................................10 Amp

Plug Type

The Model H6246 is supplied with a 5-15 plug,
similar to

Figure 2.

This machine must have a ground prong in

the plug to help ensure that it is grounded.

DO NOT remove ground prong from plug

to fit into a two-pronged outlet! If the plug

will not fit the outlet, have the proper outlet

installed by a qualified electrician.

Extension Cords

Make sure the cord is rated Standard Service
(grade S) or better.

The extension cord must contain a ground
wire and plug pin.

Use at least a 16 gauge cord. Use a 14 gauge
cord if the cord is between 51-100 feet.

SECTION 2: CIRCUIT REQUIREMENTS

Electrocution or fire could

result if this machine is

not grounded correctly or

if your electrical configu-

ration does not comply

with local and state codes.

Ensure compliance by

checking with a qualified

electrician!