beautypg.com

GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 60

background image

ADJUSTABLE FEATURES

SX TRANSISTOR CONTROLS

Page

60

January 2000

vehicle manufacturer. Card type selection must be made
within the capabilities of the control panel used and the
supporting electro mechanical devices. Failure to comply
with proper application standards could result in mis-
operation or damage to the control and/or motors.

FUNCTION 18

STEER PUMP TIME DELAY

( Push CONT 3 )

This function allows for the selection of steer pump

contactor pick up input, either seat switch or directional

switch closing, and adjustment of the time delay for the

contactor drop out.

= Pick up steer pump contactor on seat switch closure

and time delay drop out of steer pump contactor on
seat switch opening:

Range

1.5 to 65 seconds

Setting

Between 0 and 128

Resolution

0.5 seconds per set unit

Example: Setting of 20 = (20 x 0.5) + 1.5 = 11.5 seconds

= Pick up steer pump contactor on directional switch

closure and time delay drop out of steer pump
contactor on directional switch opening:

Range

0.5 to 63 seconds

Setting

Between 129 and 255

Resolution

0.5 seconds per set unit

Example: Setting of 149 = ((149-129) x 0.5) + 1.5 = 11.5

seconds

Note: Contactor drop out will be 1.5 seconds after the seat

switch opens.


FUNCTION 19

MAINTENANCE CODE TENS AND UNITS
HOURS SET

( Push CONT 4 )

This function allows for the adjustment of the tens and

units hours of the maintenance code activation time.

Range

0 to 99

Set

0 to 99

Example

9999 Hours


FUNCTION 20 MAINTENANCE CODE THOUSANDS

AND HUNDREDS HOURS SET

( Push CONT 5 )

This function allows for the adjustment of the thousands

and hundreds hours of the maintenance code activation

time.

Range

0 to 240

Set

0 to 240

Example

9999 Hours


FUNCTION 21

AUTO REGEN BRAKING C/L

(Push CONT 6)

This function allows for the adjustment of the Regen

braking current limit. High current value correlates to

shorter stopping distance.

Setting greater than 143 disables this function.

AUTO REGEN

C/L AMPS

= REGEN C/L

VAL

-

FNT 21-51

VAL

-

[(

(

6.50

[


FUNCTION 24

FIELD WEAKENING START

( Push CONT 9)

This function allows for setting the armature current at

which minimum field current will achieved .

Range

0 to 414 Amps

Setting

0 to 255

Resolution

1.625 per set unit

I

MOTOR

FWS = VAL. x 1.625

Example: Setting of 20 = 32.5 amps

FUNCTION 25

MONITOR

( Push CONT 10)

This function allows the monitoring of certain control

functions by looking directly at the RAM of the

microprocessor. Because absolute memory locations need

to be known, this function should not be used without

detailed instructions from the GE application engineer.


This function should only be adjusted by the vehicle OEM.
To ensure optimum operation of the control, this function
must be left with zero stored in this register.

FUNCTION 26

BASE RATIO

( Push CONT 11)

This function sets the ratio between armature and field

current when operating below the maximum field current

and above the Field Weakening Start point. The setting

represents the quantity of field current changed for each 1

amp of armature current changed.


Max Fld Ref

Set

Resolution Per Unit Value

40

0 to 10

0.029 amps

This manual is related to the following products: