beautypg.com

Description of status cause of status indication, Trouble-shooting diagram, Diagnostic status codes – GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 38: Traction status code, Sx transistor control page 38

background image

DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 38

January 2000

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-68

The PMT enable signal from the
auxiliary (slave) control to the master
control drops below 5V.

This status code will be displayed when the voltage at
the master PL21 drops below 5V.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

Circuits valid

for

Traction

Controller

SYMPTOM
Control will not operate.

POSSIBLE CAUSE
Auxiliary control shut down.

= Check auxiliary control for stored faults.


Verify connection between the master control P21 and the
auxiliary/slave control P10.

TROUBLE-SHOOTING DIAGRAM

POWER CONNECTIONS

LEFT CONTROL

POS

A1

F1

NEG

A2

F2

FI

E

L

D

A

R

MA

T

URE

FU1

POWER CONNECTIONS

RIGHT CONTROL

POS

A1

F1

NEG

A2

F2

FI

E

L

D

A

R

MA

T

URE

FU5

KEY SWITCH

L

P7

P1

P17

P2

P6

P9

P3

P12

P8

P4

P5

SEAT

SW.

ST

AR

T

SW.

F

O

RW

A

RD S

W

.

R

EVER

SE SW.

BRAKE SW.

P10

P21

ACC POT

STEER ANGLE

POT

BDI INTERRUPT

P18

P7

P12

P6

P2

P1

P3 P4 P5

P10

P13

LINE

P16

P15

PY7
PY12
PY10
PY11

P16

P15

AUTO REGENERATIVE

BRAKING ENABLE

PMT ENABLE OUTPUT

25

P18

STEER PUMP

CONTACTOR DRIVER

P11

REGEN OUTPUT

SIGNAL

29

50

30

66

65

PY7
PY12
PY10
PY11

PLUG PY

CONNECTIONS

PLUG PY

CONNECTIONS

8

6

15

7

10

12-1

10

SP

P1

P5

60

24

P4

12

P2

FU7

TO ACCESSORIES

FU6

P3

12-1

OSCILLATOR CARD

LEFT CONTROL

OSCILLATOR CARD

RIGHT CONTROL

3

A2

S1

TMM7

A2

A1

5

13A

A2

A1

+

-

SP

A1

A2

SP

FU4

89

88

TMM7

2

43

A1

S2

FU2

P

P











This manual is related to the following products: