DIAGNOSTIC STATUS CODES

SX TRANSISTOR CONTROL

Page 45

January 2000

TRACTION

STATUS CODE

DESCRIPTION OF STATUS

CAUSE OF STATUS INDICATION

-99

Maintenance alert and speed limit.

This status code will be displayed when the “normal”
hour meter exceeds the “maintenance alert hours”
setting for the vehicle.

MEMORY RECALL

YES

CORRECTIVE ACTIONS

TROUBLE-SHOOTING DIAGRAM

Circuits valid

for

Traction

Controller







SYMPTOM
Status code is displayed for 4 seconds when the
key switch is first turned on, and/or the vehicle
may run at a reduced speed.

CUSTOMER SELECTED SETTING WITH THE
HANDSET:

User defined status code is displayed when the
normal hour meter reading exceeds the
programmed “maintenance alert hours” setting
selected by the user

= Maintenance Code Hour Meter, Functions 19

and 20, are programmed with the Handset and
command the display of status code -99.

= If desired, Maintenance Code Speed Limit,

Function 13, can be programmed with the
Handset.


User should perform the desired maintenance
function. Re-set maintenance alert hour meter
after maintenance is performed.

NO DIAGRAM

USER SHOULD PERFORM THE DESIRED

MAINTENANCE FUNCTION