Grizzly G0548Z User Manual
Page 15
g0548zp, g1028z2, g1029z2-z2p (mfg. 12/12+)
-13-
4. Connect the motor wires, as shown in figure
6, with wire nuts. once snug, wrap electrical
tape around each wire nut and the connected
wires, to reduce the likelihood of the wire nut
vibrating loose during motor operation.
to convert the model g1028z2 to 240v:
1. disConnECt mAChinE From poWEr!
2. Cut off the included plug.
3. open the motor junction box, then remove
the wire nuts indicated in
figure 5.
voltage conversion (g1028z2 only)
the voltage conversion mUst be performed by
an electrician or qualified service personnel.
the voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram is provided on
page 42 for your
reference.
important: If the diagram included on the
motor conflicts with the one on
Page 42, the
motor may have changed since the manual was
printed. Use the diagram included on the motor
junction box cover instead.
items needed
Qty
•
phillips head screwdriver #2 ..................... 1
•
Electrical tape ............................ As needed
•
Wire nut (14 AWg x 3) ............................... 1
•
plug 6-15 .................................................... 1
5. Close and secure the motor junction box.
6. install a 6-15 plug on the end of the cord,
according to the instructions and wiring dia-
grams provided by the plug manufacturer.
—if the plug manufacturer did not include
instructions, the wiring of a generic nEmA
6-15 plug is illustrated in the
Wiring sec-
tion on
page 42.
figure 6. motor wires repositioned for 240v.
Hot
Hot
Ground
6-15 Plug
(As Recommended)
240V
<
120 VOLT (PREWIRED)
240 VOLT (REWIRED)
HiVgi 8VeVX^idg (%%B;9 &'*K68 HiVgi 8VeVX^idg (%%B;9 &'*K68 Neutral Hot Ground 5-20 Plug (Prewired) 120V GZl^gZY')%K GZl^gZY')%K Gjc 8VeVX^idg )*B;9 '*%K68 Gjc 8VeVX^idg )*B;9 '*%K68 re-Connect re-Connect Connect and tighten figure 5. location of wire nuts to be removed. Hot Hot Ground 6-15 Plug (As Recommended) 240V < 120 VOLT (PREWIRED) 240 VOLT (REWIRED) HiVgi 8VeVX^idg (%%B;9 &'*K68 HiVgi 8VeVX^idg (%%B;9 &'*K68 Neutral Hot Ground 5-20 Plug (Prewired) 120V GZl^gZY')%K GZl^gZY')%K Gjc 8VeVX^idg )*B;9 '*%K68 Gjc 8VeVX^idg )*B;9 '*%K68 remove remove
and tighten
and tighten