Grizzly G0601 User Manual
Page 28
-26-
Model g0442/g0601 (Mfg since 3/12)
24. Connect the upper and lower collection drums
together with the included metal clamp and
the provided hex bolt and nut, as shown in
figure 28.
figure 28. installing metal clamp around
collection drum.
25. place the collection drum vacuum ring
on the bottom of the collection drum (see
figure 29).
note: During operation, this ring and the
vacuum connection to the cyclone funnel will
prevent the collection bag from collapsing.
figure 29. inserting collection drum vacuum
ring.
26. install the three drum latches, as shown in
figure 30, with the (6) 10-24 x
3
⁄
8
" phillips
head screws and (6) 10-24 hex nuts included
in the box with the drum latches.
use the remaining (6) 10-24 x
3
⁄
8
" phillips
head screws and (6) 10-24 hex nuts to plug
the lower latch mounting holes.
note: To avoid bag snags, face the screw
heads inside of the drum with the shanks fac-
ing outward.
figure 30. installing the latches onto the
collector drum.
x 6
27. slide the rubber seal over the top lip of the
collection drum rim. pay special attention
to the direction of the seal, as shown in the
figure 31.
tip: Use an adhesive to keep the seal in
place.
figure 31. installing drum lid seal.
seal