Grizzly G0601 User Manual
Page 15
Model g0442/g0601 (Mfg since 3/12)
-13-
g0601 440v conversion
the Model g0601 can be converted for 440v
operation. this conversion job consists of dis-
connecting the machine from the power source,
replacing the control box assembly and the motor
cord, and rewiring the motor for 440v operation.
the necessary conversion kit (part p0601003-1v2)
for this procedure can be purchased by calling
grizzly Customer service at (800) 523-4777.
All wiring changes must be inspected by a quali-
fied electrician before the machine is connected
to the power source. if you need help at any time
during this procedure, call grizzly tech support at
(570) 546-9663.
to rewire the model g0601 for 440v opera-
tion:
1. disConneCt MAChine FroM poWer!
2. record the wire colors and connections of
the four incoming power wires and the four
outgoing motor wires inside the 220v control
box, as illustrated in
figure 3. you can also
refer to the
g0601 Wiring diagram on page
51 for a more complete wiring illustration.
A1
Ground
2T1
6T3
14NO
4T2
1L1
5L3
13NO
3L2
NHD C-18D
2T1
4T2
6T3
98
97
A2
96
O
R
95
21
22
23
25
NTH-25
A2
figure 3. power and motor wire connections (all
other connections hidden for clarity).
4 incoming
power Wires
4 outgoing
Motor Wires
3. disconnect these eight wires, then replace
the 220v control box with the 440v control
box.
4. replace the old motor cord with the new, and
reconnect the wires as recorded in
step 2.
5. remove the old motor cord from the motor.
6. rewire the motor as shown inside the motor
junction cover and attach the new motor
cord.
note: The reference wiring diagram on
Page 51 was current at the time of printing,
but always use the wiring diagram provided
inside the motor junction box, as it will reflect
any changes to the motor shipped with the
machine.