beautypg.com

GE E4LE User Manual

Page 16

background image

11

2.15

Autoflush Timer

2.15.1 Programming the Autoflush Timer

The Autoflush timer clock operates and displays in real time, but the Autoflush
feature will only work when the RO machine is operating. When the machine
is operating in the Autoflush Mode, the total flow through the machine is
increased. This provides extra cross flow which flushes the loose foulants
from the surface of the membrane elements. When the machine is operating
in the Autoflush Mode a slight drop in permeate production, as well as a
decrease in the primary and final pressures may be observed. An ideal way
to set the timer up is to program ten Autoflush sequences, with a 10 to 15
minute duration, per 24 hours. To do this, follow the procedure below.

2.15.2 Setting Up the Autoflush Timer Clock

IMPORTANT:

Before proceeding with setting the timer and programming
the unit, press the RESET KEY to clear all data. After press-
ing the RESET KEY, the display may show

A.M.

, this is in mili-

tary time mode.

If the machine is in Military Time, do the following:

Figure 2.2

Setting-Up the Correct Time

on the Autoflush Timer

SELECTING AM/PM OR MILITARY TIME

After pressing reset, the display may show
A.M.(right). The numbered day symbols will be flash-
ing ON and OFF.

If the display does not show A.M., it is in military time
mode (24:00 hr.). To change to A.M./P.M. mode, press
and hold the h

Key and press the

± 1h Key once, A.M. will appear in the display.

If display is in A.M.. mode and military mode is
desired, press and hold the h Key, press the
± 1h Key once.

This manual is related to the following products: