beautypg.com

Outlet thermistor, Outlet thermostat – GE DPGT750EC/GC User Manual

Page 31

background image

– 31 –

Outlet Thermistor

The outlet thermistor is located on the blower
housing on both the gas and electric models.

Outlet Thermostat

The outlet thermostat is located on the blower
housing on both the gas and electric models (see
photos.)

The outlet thermostat monitors outgoing air
temperature.

If the outlet thermostat reaches a temperature
beyond its maximum temperature rating, it will
trip and disable the heating function only.

The heating function will be restored when the
outlet thermostat cools and resets.

The outlet thermostat on the electric model
has a trip temperature of 189°F (87°C) and a
reset temperature of 153°F (67°C).

The outlet thermostat on the gas model has a
trip temperature of 185°F (85°C) and a reset
temperature of 149°F (65°C).

To remove the outlet thermostat:

1. Remove the

Top Cover

,

Front Panel

, and

Drum

.

2. Disconnect the thermostat wiring.

3. Remove 2 Phillips head screws that hold the

outlet thermostat to the blower housing.
Remove the outlet thermostat.

Outlet Thermistor

Outlet Thermistor

Outlet Thermostat

Outlet Thermostat

The inlet safety thermostat monitors incoming
air temperature.

If the thermostat reaches a temperature
beyond its maximum temperature rating, it will
trip and disable all dryer functions except the
drum lamp.

The inlet safety thermostat must be reset
manually by pressing the reset button on the
back of the thermostat (see photos).

The inlet safety thermostat on the electric
models has a trip temperature of 212°F
(100°C).

The inlet safety thermostat on the gas models
has a trip temperature of 266°F (130°C).

To remove the safety thermostat:

1. Remove the

Top Cover

,

Front Panel

, and

Drum

.

2. Disconnect the safety thermostat wiring.

3. Remove the 2 screws that hold the safety

thermostat in place. Remove the safety
thermostat.

The outlet thermistor measures outgoing air
temperature and responds to temperature
changes.

The outlet thermistor provides temperature
change information to the electronic control
board.

The electronic control board makes heating
decisions based on this information.

At room temperature the outlet thermistor has
a resistance value of 10 K

+/- 3%.

To remove the outlet thermistor:

1. Remove the

Top Cover

,

Front Panel

, and

Drum

.

2. Disconnect the thermistor wiring.

3. Remove the screw that holds the thermistor in

place. Remove the thermistor.