beautypg.com

User instructions, Gazco flue sure system, The flame failure device – Stovax Brunel 8050 User Manual

Page 6

background image

6

USER INSTRUCTIONS

AR0900

6

6.4 • Place three coals equally spaced on the rear of the fuel

bed so they touch the rear panel, Diagram 7

AR0901

7

6.5 • Place five coals on the front of the fuel bed so they rest

on the front coal effect and lean against the vertical fingers,
Diagram 8

AR0902

8

AR0900

6

6.4 • Place three coals equally spaced on the rear of the fuel

bed so they touch the rear panel, Diagram 7

AR0901

7

6.5 • Place five coals on the front of the fuel bed so they rest

on the front coal effect and lean against the vertical fingers,
Diagram 8

AR0902

8

6.6 • Place the remaining four coals between the two rows of

coals

• Rotate the coals to ensure they are secure on the fuel
bed, Diagram 9

AR0903

9

6.7 • Close the door and tighten the bolt and domed nut

NOTE: ENSURE THAT THE COALS ARE POSITIONED, AS
DETAILED ABOVE. ONLY USE THE CORRECT AMOUNT
OF COALS, AS SPECIFIED IN THE DIAGRAMS

7. GAzCO FLUE SURE SYSTEM

7.1 The stove is fitted with the Gazco Flue Sure System, which

will act to cut off the gas supply to the burners in the event

of incorrect operation of the flue. If the system acts to cut

off the gas supply, this indicates that there is insufficient flue

pull. If this occurs a minimum of 10 minutes should be

allowed before trying to relight. Continued operation of this

safety device means there may be a serious problem with

the flue system. A qualified gas engineer should inspect this.

Do not use the stove until an engineer says it is safe to

do so.

8. THE FLAME FAILURE DEVICE

8.1 This is a safety feature incorporated in all GAZCO fires,

which automatically switches off the gas supply if the pilot

light goes out and fails to heat the thermocouple.