6.4 • Place three coals equally spaced on the rear of the fuel
bed so they touch the rear panel, Diagram 7
AR0901
7
6.5 • Place five coals on the front of the fuel bed so they rest
on the front coal effect and lean against the vertical fingers,
Diagram 8
AR0902
8
AR0900
6
6.4 • Place three coals equally spaced on the rear of the fuel
bed so they touch the rear panel, Diagram 7
AR0901
7
6.5 • Place five coals on the front of the fuel bed so they rest
on the front coal effect and lean against the vertical fingers,
Diagram 8
AR0902
8
6.6 • Place the remaining four coals between the two rows of
coals
• Rotate the coals to ensure they are secure on the fuel
bed, Diagram 9
AR0903
9
6.7 • Close the door and tighten the bolt and domed nut
NOTE: ENSURE THAT THE COALS ARE POSITIONED, AS
DETAILED ABOVE. ONLY USE THE CORRECT AMOUNT
OF COALS, AS SPECIFIED IN THE DIAGRAMS
7. GAzCO FLUE SURE SYSTEM
7.1 The stove is fitted with the Gazco Flue Sure System, which
will act to cut off the gas supply to the burners in the event
of incorrect operation of the flue. If the system acts to cut
off the gas supply, this indicates that there is insufficient flue
pull. If this occurs a minimum of 10 minutes should be
allowed before trying to relight. Continued operation of this
safety device means there may be a serious problem with
the flue system. A qualified gas engineer should inspect this.
Do not use the stove until an engineer says it is safe to
do so.
8. THE FLAME FAILURE DEVICE
8.1 This is a safety feature incorporated in all GAZCO fires,
which automatically switches off the gas supply if the pilot
light goes out and fails to heat the thermocouple.