CONNECTING TO POWER

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

5

Plug the operator into a properly grounded
electrical outlet. (Fig. 5-1)

• To reduce the risk of electrical shock, this equipment

has a grounded type plug that includes a third
(grounding) pin. This plug will only fit a grounded type
outlet. If you do not have a grounded outlet, contact
a qualified licensed electrician to install one. DO NOT
alter the plug in any way. The door operator must be
properly grounded in order to prevent personal injury
and damage to the components.

• DO NOT remove motor cover. All work performed

on motor must be done by a trained professional
service technician.

WARNING

Check local building codes to make sure that you

are not required to have your garage door operator
permanently wired, with circuit breaker protection. If
building codes require door operator to be
permanently wired have a qualified licensed
electrician connect power with permanent wiring.

CAUTION

WITH GROUNDED PLUG:

5" fr

om

floor

FIG. 5-4 Check Safety Beam Alignment

.

FIG. 5-1 Connect to power

.

INFRARED PROTECTION FUNCTION

1. When the garage door is opening, its movement

will not be influenced if the safety beam is
obstructed.

2. If the safety beam is obstructed before the

garage door closes, the door will not close.

3. When the garage door is closing, if safety beam is

cut off by people or obstacle, the garage door will
reverse automatically to its fully opened position.
(Meanwhile, the opener light will keep blinking until
door moves to its fully opened position.)

4. If the Safety Beam System fails, loses power, or

is installed improperly, you will have to press
and hold the wall control "close" button until the
door reaches its fully closed position. The LED
indicator light on the power head will be green
and blink twice (Pattern: ☼☼ pause ☼☼ pause)
to inform you to eliminate problem first.
Otherwise, the door will reverse automatically to
its fully opened position if you release the
"close" button on the wall control during the
closing movement.

FIG. 5-2

Remove motor cover.

WITH PERMANENT WIRING:

Instructions for Electrician.
• Remove power from circuit.
• Remove rear cover and motor cover.

– Remove four motor cover screws (Fig. 5-2).

• Remove existing power cord and strain relief

from the 7/8" dia. hole and discard. (Fig. 5-3)

• Connect permanent wiring to power head using

7/8" diameter hole.
White to white/black to black/ground to green.
– Use only UL recognized wire nuts.

• Wires inside the power head must be at least 6"

in length.

• Replace motor cover and rear cover and

re-energize the circuit.

NOTE: The Genie Company is not responsible for
charges resulting from work preformed by an
independent electrician.

Check Safety Beam alignment (Fig. 5-4).
• Insure that no part of door or its hardware is

in path between lenses of source and sensor.

• Insure that tops of lenses are between 5" - 6"

above the floor (Fig. 5-4). The brackets are
flexible, and can be adjusted slightly if needed.

• Adjust the Red LED transmitter by aiming the

unit directly at the Green LED receiver. Use the
adjustment screw located on the top of the
transmitter housing to make adjustments.

• The Red LED transmitter will blink if there is a

misalignment. When the LED units are aligned
the Red LED will remain ON continuously.

• After the alignment is finished tighten the

adjustment screws on both sensors.

Motor Cover Screws

FIG. 5-3

Power cord strain relief.

• Do NOT use an extension cord.
• Do NOT use a portable generator. This product

is designed to operate using standard
household current.

• Do NOT use alternate power supplies.

CAUTION

WITH POWER SUPPLIED: