3.Securely fasten wires.

• Securely fasten wires to ceiling and

wall using insulated staples provided.
– Use insulated staples.
– Staples should be snug only.

• If rear cover is attached to power head,

remove it.

• On power head:

– Route wall control wires through wire guide.
– Split and strip ends of wire (Fig. 3-2 on

previous page).

– Insert wire into terminal holes and lightly press in

the orange locking clips above each terminal
hole. (You can use a pencil or small screwdriver
to comfortably press in locking clips.) The white
wire into #2 terminal hole and striped wire into
the #1 terminal hole.

– Confirm wire lock by lightly tugging on the wire.

The wire should remain in the terminal hole.

Do NOT install rear cover yet.

4. Mounting.

• Fasten wall control to wall with 2 screws

(provided) (Fig. 3-4).

• Remove protective backing from "Entrapment"

warning label (Fig. 3-5). The "Entrapment" label
is located in the center of this manual.
– Stick label on wall near wall control.

FIG. 3-4

Mounting wall control.

Insulated

Staple

+ –

P

B

Infared Sensor

1

2

3

4

5

6

FIG. 3-3 Insert wires

.

(Power Head With Rear Cover Removed)

1

2

3

4

Terminal

Holes

Locking

Clips

5

6

FIG. 3-5

Mounting Entrapment warning label.