Genie 1022 User Manual
Page 15
PN# 3642036212, 8/09/2007
15
3.Securely fasten wires.
• Securely fasten wires to ceiling and
wall using insulated staples provided.
– Use insulated staples.
– Staples should be snug only.
• If rear cover is attached to power head,
remove it.
• On power head:
– Route wall control wires through wire guide.
– Split and strip ends of wire (Fig. 3-2 on
previous page).
– Insert wire into terminal holes and lightly press in
the orange locking clips above each terminal
hole. (You can use a pencil or small screwdriver
to comfortably press in locking clips.) The white
wire into #2 terminal hole and striped wire into
the #1 terminal hole.
– Confirm wire lock by lightly tugging on the wire.
The wire should remain in the terminal hole.
• Do NOT install rear cover yet.
4. Mounting.
• Fasten wall control to wall with 2 screws
(provided) (Fig. 3-4).
• Remove protective backing from "Entrapment"
warning label (Fig. 3-5). The "Entrapment" label
is located in the center of this manual.
– Stick label on wall near wall control.
FIG. 3-4
Mounting wall control.
Insulated
Staple
+ –
P
B
Infared Sensor
1
2
3
4
5
6
FIG. 3-3 Insert wires
.
(Power Head With Rear Cover Removed)
1
2
3
4
Terminal
Holes
Locking
Clips
5
6
FIG. 3-5
Mounting Entrapment warning label.