Additional safety rules

when using water

cooling system

The Sliding Tile Cutting Saw

has been fitted with a Residual

Current Device (RCD) safety

switch designed to immediately

switch the electricity off if a fault

is detected to avoid

the risk of a potentially

fatal shock.

WARNING

. To be

effective, the RCD

must ALWAYS be

in good working

condition. (see

‘Testing your safety

switch’

for further

details).

The RCD device is not designed for outdoor use,

INDOOR USE ONLY

Electricity can be dangerous, the use of an RCD device

should not be regarded as a substitute for basic electrical

safety precautions

You must unplug all equipment to achieve isolation before

any inspection or repair of that equipment is attempted

Please seek advice from an electrical contractor or

a GMC Technical service person if the RCD device

repeatedly trips, or fails to trip in accordance with the

instructions provided

Never immerse your RCD device in water, and do not

expose the unit to rain

Do not connect your RCD device to an extension cord

You must take proper care of your RCD device, take care

not to drop it on hard surfaces as it may crack and/or

damage the internal components

Testing your safety switch

IMPORTANT.

Ensure the RCD is tested upon every use.

It is essential that the safety switch is tested to ensure it

is functioning correctly. We strongly recommend that this

procedure is conducted without fail before every use.
1. Plug your RCD device into a fixed 230-240Vac ~ 50Hz

power wall socket outlet and switch on.

WARNING

. The RCD device should be connected directly to

a mains socket outlet only, never connect your RCD device

to an extension cord.
2. To set the RCD into the ON

position, press the green

“RESET” button. The “RED

ON” illuminator will then

transform from a clear colour

to a red colour.

3. Press the “TEST” button.

Doing this will make the RCD

device trip immediately, and

will remove the flow of power

to the connected appliance. It

then will change the “RED ON”

illuminator to a clear colour, if

this occurs it confirms that the

RCD device is operational.

If the RCD device does not trip

as per the explanation above,

please contact the GMC help line for assistance.

4. Upon tripping, you must reset RCD to the “ON” position.

Press the green “RESET” button, the “RED ON” illuminator

will transform from a clear colour to a red colour.

IMPORTANT.

If your RCD device does not operate correctly

in accordance with the instructions provided, you must stop

using the device and contact the GMC help line.